SVOLT 51.2V 106Ah A-Grade Lithium Battery

The SVolt 51.2V 106Ah A-Grade Lithium Battery is manufactured by a world-leading manufacturer using A-Grade Battery cells. This allows superior performance, capacity, and reliability. Using state of high power A-Grade cell technology, the Lithium Battery is designed for environmentally sensitive areas and is committed to recycling.

Suitable for industrial, residential, commercial, and private applications. The maintenance-free construction and advanced design features make the Lithium Battery the definitive choice for a wide variety of markets – Like solar and renewable energy storage for electric vehicles, industrial equipment, medical equipment, telecommunications, TVs, and UPS systems.

Features:

  • A-Grade Cell Technology
  • Maintenance-free
  • Environmental Friendly
  • Wide Variety of Markets
  • Renewable Energy
  • 7 Protection Features
  • Built-in Battery Management System
  • Mountable

Mechanical Characteristics

  • Cell Type: N-Type Mono-Crystalline
  • No. of Cells: 144 (6×14)
  • Dimensions: 2278x1134x35mm (89.53×44.65×1.38 inch)
  • Weight: 28kg (61.73 lbs)
  • Front Glass: 3.2mm, Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass
  • Frame: Anodized Aluminium Alloy
  • Junction Box: IP68 Rated
  • Output Cables: TUV 1×4.0mm (+):300mm, (-): 300mm or Customized Length

Battery Specifications:

  • Battery Type-Chemistry: LiFePO4
  • Nominal Voltage: 51.2V
  • Nominal Capacity: 106Ah
  • Energy Density: 5427.2Wh
  • Terminal Type: M6
  • Terminal Torque: 8.5NM
  • Case Material: Metal
  • BMS Built-in: Yes
  • Internal Resistance: <30mΩ
  • Efficiency – Round Trip: >99.5%
  • Self Discharge per Month: <3%
  • Max Parallel Connectors: 16Pcs
  • Series Connections: Not Allowed
  • Cycle Life(0.2°C, 25°C @ 80% DOD): >4000 Cycles
  • Discharge Temperature: -20°C to 65°C
  • Charge Temperature: 0°C to 45°C
  • Storage Temperature: -10°C to 30°C
  • Voltage Window: 44.8 – 57.6V
  • Recommended Charge Voltage: 57.6 ±0.20V
  • Max Charge Voltage: 58.4 ±0.20V
  • Recommended Charge Current: 50A
  • Max Continuous Charge Current: 100A
  • Recommended Discharge Voltage: 44.8 ±0.20V
  • Max Discharging Voltage: 43.2 ±0.20V
  • Max Continuous Discharge Current: 100A
  • Peak Discharge Current: 120A (5s±2s)
  • Dimensions: L 566 x W 402 x H135 mm
  • Weight: 47Kg

BMS Characteristics:

  • Primary Charging Protection: (Current: 80A) (Delay Time:1000ms)
  • Secondary Charging Protection: (Current: 100A) (Delay Time:500ms)
  • Primary Discharging Protection: (Current: 110A) (Delay Time: 5s±2s)
  • Secondary Discharging Protection: (Current: 120A) (Delay Time: 5s±2s)
  • Over Charge Voltage Protection: (Voltage: 58.4V) (Delay Time:500ms)
  • Over Discharge Voltage Protection: (Voltage: 43.2V) (Delay Time:500ms)
  • Temperature Protection: (Temperature: ≥95°C) (Recover: ≤85°C)
  • Communication Port: Major RS485,CAN/Dryport